Download Adobe ReaderOptimus Family

The Optimus family of subsea bolt tensioning equipment consists of every thing you need to bolt tension & pull subsea flanges. Download the individual data sheets for more information.

PDF Download 1PDF Download 2PDF Download 3PDF Download 4

Air Driven Pump Unit

Approximate size – 42cm x 42cm x 45cm
Weight (reservoir empty) – 22.5kg
Reservoir capacity – 9 litres
Hydraulic piston diameter – 6.35mm
Hydraulic piston area – 31.67mm²
Volume per stroke – 999.6mm²

Recommended Oil

ISO Grade 10, 32 and 68
Example: Shell Morlina oil 10

Air Consumption

When operating from zero to rated hydraulic pressure, air consumption will be approximately 28ft³/Min of free air at 100 PSI input. At lower air pressures and higher hydraulic pressures, air consumption will be reduced proportionally to flow rates included.

Air Pump


Tentec Mini Air Driven Pump Unit

Tentec Air Driven Pump Units operate on the simple but efficient principle of power magnification through the use of differential areas. A relatively large air-operated piston drives the smaller piston, which provides fluid flow at high pressures. All Tentec air driven pump units are fitted into an easily transportable, tubular steel frame.

The pump units are available, fitted with a large choice of pressure gauges and are supplied complete with an air pressure regulator which can be set to stall the pump unit when it reaches the pressure required for each particular tensioning application.

Technical Specifications

Tentec supply many different air driven pump units, of varying pressure and fluid discharge specifications.

This document details the main tensioning air pump, the model HTT.627x Series.

The Tentec standard tensioning pump configuration is the model HTT.6271, with a maximum working pressure of 1500bar fitted with a suitable gauge and outlet connection.

For higher pressure needs the model HTT.627x series pump can be configured with a 2275bar max working pressure, fitted with a suitable gauge and outlet connection. Part number HTT.6272

Tabular Data

Note: When operating from 0 to rated hydraulic pressure, air consumption will be approx 28scfm of free air at 100psi input. At lower air pressures and higher hydraulic pressure, air consumption will reduce proportionaly

Approximate Rate of Discharge

Diagram

Specification

Tabular Data

Hand Lever

Previous Page
Tentec products are subject to continual development and Tentec reserve the right to make changes in the specification and design of there products without prior notice. All rights reserved. Reproduction in whole or in part without the permission of Tentec Limited is prohibited.

XHTML Vaild